Skip to main content

Reliability of last menstrual period recall, an early ultrasound and a Smartphone App in predicting date of delivery and classification of preterm and post-term births

Abstract

Background

A reliable expected date of delivery (EDD) is important for pregnant women in planning for a safe delivery and critical for management of obstetric emergencies. We compared the accuracy of LMP recall, an early ultrasound (EUS) and a Smartphone App in predicting the EDD in South African pregnant women. We further evaluated the rates of preterm and post-term births based on using the different measures.

Methods

This is a retrospective sub-study of pregnant women enrolled in a randomized controlled trial between October 2017-December 2019. EDD and gestational age (GA) at delivery were calculated from EUS, LMP and Smartphone App. Data were analysed using SPSS version 25. A Bland–Altman plot was constructed to determine the limits of agreement between LMP and EUS.

Results

Three hundred twenty-five pregnant women who delivered at term (≥ 37 weeks by EUS) and without pregnancy complications were included in this analysis. Women had an EUS at a mean GA of 16 weeks and 3 days). The mean difference between LMP dating and EUS is 0.8 days with the limits of agreement 31.4–30.3 days (Concordance Correlation Co-efficient 0.835; 95%CI 0.802, 0.867). The mean(SD) of the marginal time distribution of the two methods differ significantly (p = 0.00187). EDDs were < 14 days of the actual date of delivery (ADD) for 287 (88.3%;95%CI 84.4–91.4), 279 (85.9%;95%CI 81.6–89.2) and 215 (66.2%;95%CI 60.9–71.1) women for EUS, Smartphone App and LMP respectively but overall agreement between EUS and LMP was only 46.5% using a five category scale for EDD-ADD with a kappa of .22. EUS 14–24 weeks and EUS < 14 weeks predicted EDDs < 14 days of ADD in 88.1% and 79.3% of women respectively. The proportion of births classified as preterm (< 37 weeks) was 9.9% (95%CI 7.1–13.6) by LMP and 0.3% (95%CI 0.1–1.7) by Smartphone App. The proportion of post-term (> 42 weeks gestation) births was 11.4% (95%CI 8.4–15.3), 1.9% (95%CI 0.9–3.9) and 3.4% (95%CI 1.9–5.9) by LMP, EUS and Smartphone respectively.

Conclusions

EUS and Smartphone App were the most accurate to estimate the EDD in pregnant women. LMP-based dating resulted in misclassification of a significantly greater number of preterm and post-term deliveries compared to EUS and the Smartphone App.

Peer Review reports

Background

A reliable expected date of delivery (EDD) is important for pregnant women in planning for a safe and uneventful delivery and critical for clinical management of obstetric emergencies [1, 2]. In an implementation study of the Intergrowth-21 gestational dating in Kenya, all respondents interviewed reported that the EDD helped them to prepare for delivery financially and logistically [3]. According to the WHO guidelines pregnant women should have at least one ultrasound (US) before 24 weeks in pregnancy to determine the gestational age (GA), EDD and identify fetal anomalies and poor fetal growth [4]. In low and middle income countries (LMIC) the availability of an ultrasound machine and ultrasound expertise are often limited to secondary and tertiary level facilities [3,4,5,6] and pregnant women attending primary health care clinics are referred to hospitals and Midwifery Outpatient Units for an US. However, long waiting times and financial constraints together with late antenatal attendance often delay an ultrasound examination to after 24 weeks of pregnancy [6].

In the case of first visit antenatal attendees, the midwife would have to depend on the accurate recall of LMP date and determine gestational age and EDD using a “pregnancy wheel”, or on symphysis-fundus height (SFH) measurements if the LMP is unknown or unreliable [7]. SFH measurements are further complicated by small for gestational age fetuses and high body mass index (BMI) [8]. Upon receipt of an US report at a subsequent antenatal visit, the midwife is required to adjust the EDD originally determined using LMP date. In the event of a major discrepancy between the LMP dating and the US report, midwives will need to ascertain which of the two measures will be more accurate. In 2016, the American College of Obstetricians and Gynecologists (ACOG) released a new EDD Calculator smartphone application (Smartphone App) that reconciles discrepancies in due dates between the first ultrasound and the date of the LMP [1].

Previous studies comparing second trimester ultrasound with LMP dating found ultrasound, on average, resulted in lower GA estimates [9, 10]. A recent South African study compared dating by LMP, SFH and EUS and concluded that pregnancy dating by ultrasound, including those in more advanced pregnancy than currently permitted, is recommended since all non-ultrasound based estimations of GA were considerably less accurate [11].

In clinical trials and pregnancy surveillance registries investigating safety and efficacy of new treatment regimens in preventing infection and adverse pregnancy outcomes, preterm births as defined by GA < 37 weeks and severe preterm (GA < 34 weeks) births are primary clinical outcomes [12, 13]. Many multi-country pregnancy clinical trials and pregnancy surveillance protocols in LMICs depend on GA dating using the LMP and only confirmed by ultrasound, when available [14]. As a result, inconsistencies in GA assessment within and between studies could lead to variable and incomparable outcomes [15,16,17]. There are several smartphone apps for parents-to-be and these apps are intended to be informative for better pregnancy outcomes. There are no validity studies of pregnancy dating apps for service providers.

In this retrospective data analysis, we evaluated the accuracy of LMP recall, an EUS and the ACOG smartphone app in predicting the EDD in a South African cohort of pregnant women not living with Human Immunodeficiency Virus (HIV). We further compared the preterm and post-term birth rate as determined by each method.

Methods

This is a secondary analysis of data collected in a randomized controlled trial (RCT) that was designed to determine the safety of Tenofovir disoproxil fumarate/Emtricitabine (TDF/FTC) in pregnancy when used as pre-exposure prophylaxis in healthy pregnant women not living with HIV (ClinicalTrials.gov NCT03227731). The RCT is being conducted at a Research Clinic in Durban, South Africa (SA) and enrolled a total of 540 pregnant women between October 2017 and December 2019. Women were 18 years or older, confirmed pregnant, confirmed testing negative for HIV infection, booked for antenatal care < 24 weeks of gestation, without life-threatening co-morbidities and at minimal risk for obstetric complications. HIV seronegative pregnant women booking for antenatal care at local primary health clinics in Umlazi, a peri-urban township in Durban, were referred to the Umlazi Research Clinic based at the Prince Mshyeni Memorial Hospital (PMMH), Durban if they were interested in participating in the parent RCT. Antenatal screening including gestational age determination was done at the research clinic. Gestational age was determined by recall of last menstrual period date and an ultrasound. Women who were eligible and consented to participation in the RCT continued with the antenatal care provided at the research clinic. Women delivered at PMMH and continued with postpartum care at the Research Clinic.

For this sub-study, the following exclusion criteria were applied:

  • the recollection of the date of the LMP was unknown or deemed unreliable

  • planned cesarean delivery

  • induction of labour prior to 37 weeks

  • preterm delivery (< 37 weeks based on EUS dating) occurred

  • there was a diagnosis of polyhydramnios, abruptio placentae

  • multiple pregnancy, intra-uterine growth restriction and/or fetal anomaly

  • insufficient clinical notes

At screening for the parent study, all pregnant women underwent an obstetric ultrasound examination, using the Portable PC-Based TECHNO 8000 Ultrasonic Diagnostic Instrument, at the research clinic. Upon confirmation of a viable intra-uterine pregnancy, standard fetal biometry (a crown-rump length (CRL) in the first trimester and a biparietal diameter (BPD Outer-Inner), abdominal circumference (AC) and femur length (FL) in the second trimester were measured. With these measurements, the EDD and the average GA was also expressed in the report [18]. The ultrasound was performed by a single sonographer. In addition to an obstetric and general examination, the pregnant woman also provided the date of her last LMP, if known. For this sub-study analysis, an EDD was calculated from the EUS, LMP and the Smartphone App. The ACOG smartphone app can be downloaded from the ACOG website (https://www.acog.org/membership/member-benefits/acog-app) or from Google play (https://play.google.com/store/apps/details?id=vspringboard.acog.activity). The App is free of charge and does not need internet access. Among other features on the App, the “Estimated Due Date Calculator” based on guidance from ACOG and others, uses data from last menstrual period and first accurate ultrasound to determine estimated due date and target date for gestational age. The App has the ability to reconcile the discrepancy in due dates between the ultrasound-determined dates and the date of the last menstrual period as and when redating is recommended [1]. Further guidance to redating is provided in the ACOG Committee Opinion and is based on the timing of the ultrasound and the discrepancy between LMP and US dating [1].

Delivery data such as actual date of delivery (ADD), mode of delivery and birth weight were extracted from the hospital records. GA at delivery was calculated using the EUS, LMP and the ACOG Smartphone App independent of each other.

Definitions

Reliable LMP: By convention, pregnancies are dated in weeks starting from the first day of a woman's last LMP. The questions that were routinely asked at the research clinic when determining reliability of the LMP were:

  • have you had regular menstrual periods over the last 6 months

  • were you on any hormonal therapy including contraceptive in the last 6 months

  • were you breast feeding in the last 6 months

  • were you pregnant in the last 6 months

  • was the conception spontaneous

EUS: Early obstetric ultrasound is an ultrasound examination before 24 weeks gestation.

EDD based on LMP: The estimated/expected date of delivery, also known known as estimated due date or simply known as due date, is a term describing the estimated date of confinement usually corresponding to 40 weeks (279 days) from the 1st day of the last normal menstrual period.

EDD based on EUS: The estimated/expected date of delivery corresponding to 40 weeks from the gestational age determined by EUS.

ADD: Actual date of delivery.

GA at Delivery in weeks and days: Is calculated using the following formula: 280 days – (EDD-ADD).

Preterm Birth: gestation < 37 complete weeks.

Post-term Birth: gestation > 42 complete weeks.

Ethics approval and consent to participate

The Institutional Review Board of University of KwaZulu-Natal approved the study (Ref BE 00000817/2019, a sub-study of BFC 243/16). For this retrospective data analysis of de-identified data, a written informed consent was waived by the Institutional Review Board of University of KwaZulu-Natal.

Data were analysed using SPSS version 25. Descriptive statistics such as frequencies and percentages were used to summarise categorical variables. Central tendency and dispersion of data were measured using means and standard deviations for normally distributed variables and medians and interquartile ranges for skewed variables. A p-value less than 0.05 was considered statistically significant. We evaluated the concordance of the LMP, EUS and the ACOG app in predicting the expected date of delivery and calculated the concordance correlation coefficient (ccc) with 95% confidence intervals as well as the Bland–Altman limits of agreement [19]. We also categorized the EDD-ADD difference into five intervals (≤ -15, -14 to -8, -7 to 7, 8 to 14, ≥ 15 days) and used the kappa statistic to evaluate the agreement between the LMP and EUS as a robust measure since the distribution of the EDD-ADD difference of the two measures were different.

Results

Of the 540 women enrolled in the parent study, 325 women met the eligibility criteria for the sub-study analysis. The 325 women had an ultrasound performed at a mean GA of 16 weeks and 2 days, and all had an EUS (< 24 weeks). The mean (SD) age of the women was 23.7 (4.5) years with the majority (79.1%) having an education level of matriculation or higher (Table 1). The mean (SD) BMI was 27.5 kg/m2 (5.8) and 31% of the cohort were obese (BMI ≥ 30 kg/m2). The mean (SD) birthweight of the neonate was 3200 g (400). The median estimated GA at birth was 277 days (week 39 + 4), 276 days (week 39 + 3) and 277 days (week 39 + 4) by EUS, LMP and Smartphone App respectively.

Table 1 Study population characteristics by 1st and 2nd trimester antenatal booking (N = 325)

The mean number of days from initial antenatal assessment to expected delivery was 148.2 ± 30.1 (range 45 – 235) and 147.4 ± 27.1 (range 79 – 237) days for LMP and EUS dating respectively. Figure 1 shows a Bland Altman plot for the two methods LMP and EUS (Concordance Correlation Co-efficient 0.835; 95% CI 0.802, 0.867). The mean difference between LMP dating and EUS is 0.8 days with the limits of agreement 31.4 to 30.3 days. The mean and SD of the marginal time distribution of the two methods differ significantly (p = 0.00187).

Fig. 1
figure 1

Limits of agreement between LMP and EUS (Bland JM, Altman DG (1986)

The median estimated GA at birth was 277 days (week 39 + 4) and 276 days (week 39 + 3) gestation for the EUS and LMP dating respectively. Compared to LMP, EUS derived GA at delivery was slightly longer (mean of 277 days vs. 276 days), less variable (standard deviation of 8 days vs. 18 days) and had a narrower range (247 – 308 days vs. 220 – 374 days). The proportion of births classified as preterm (< 37 weeks gestation) was 9.9% (95%CI 7.1 – 13.6) by LMP and 0.3% (95%CI 0.1–1.7) by ACOG Smartphone App. The proportion of post-term (> 42 weeks gestation) births was 11.4% (95%CI 8.4–15.3), 1.9% (95%CI 0.9–3.9) and 3.4% (95%CI 1.9–5.9) by LMP, EUS and Smartphone respectively. Labour was induced in 24 (7.4%) women, this including one post term birth and 23 term births as classified by EUS.

EDDs were within 14 days of the ADD for 287 (88.3%; 95%CI 84.4–91.4), 279 (85.9%; 95%CI 81.6–89.2) and 215 (66.2%; 95%CI 60.9–71.1) women for EUS, ACOG Smartphone App and LMP respectively (Table 2). An EUS performed 15 – 24 weeks gestation predicted EDDs within 14 days of ADD in 89.7% (95%CI 85.2–93.2) of women versus 84.2% (95%CI 74.4–91.3) (OR 0.61; 95%CI 0.29–1.25; p = 0.125) with an EUS performed before14 weeks (Table 2). A comparison of the difference in days between ADD and EDD for LMP, EUS and ACOG Smartphone app using the Bland Altman analysis suggest a poor concordance correlation between LMP and EUS (ccc r = 0.35; 95%CI 0.28–0.41). There was also poor agreement in the difference of days (ADD-EDD) between LMP and EUS when comparing the categorical distribution using 7-day intervals (overall agreement = 46.5% with kappa = 0.22 with SE = 0.03) (Table 3 and Fig. 2).

Table 2 Predictive accuracy of the Estimated Date of Delivery (EDD) for the Actual Date of Delivery (ADD) for 7 and 14 day windows
Table 3 Cross-tabulation of categorized EDD-ADD differences for LMP and EUS (cell frequencies and percentages)
Fig. 2
figure 2

Kernel density estimates of deviation of the actual delivery date from the estimated delivery date of delivery calculated from an ultrasound (EUS), last menstrual period (LMP) and ACOG App

Discussion

In this sub-study of healthy pregnant women not living with HIV, we found that EDDs derived from an EUS performed < 24 weeks gestation and using the ACOG Smartphone App were both within 2 weeks of actual delivery in more than 85% of the study population as opposed to LMP derived EDDs in 66% of the population. The mean EDD is very similar between the methods but at an individual participant level the agreement is poor with limits of agreement > 30 days which indicates large differences given the short time frame of pregnancy. In addition, we report the similar marginal predictive accuracy of EDDs within 2 weeks of ADD (-14 to 14 days) for LMP and EUS (84.2% vs 89.7%) but when comparing categorized EDD-ADD difference head to head the agreement is also poor (kappa = 0.22). Estimated GA at birth derived from the LMP resulted in 10% of births to be misclassified as preterm (< 37 weeks) and 11% post-term (> 42 weeks). There was one preterm birth with EDD determined on the ACOG Smartphone App.

Several studies in the past decade have assessed the accuracy of LMP dating in comparison to an ultrasound [11, 12, 20,21,22,23,24,25] and none that evaluated the use of a Smartphone app. In the majority of the studies, LMP is less reliable because of poor recall, irregular menstrual cycles and prior use of hormonal contraception [7, 26,27,28]. Our findings of the mismatch between EDD and ADD using LMP dating alone in this healthy cohort of pregnant women are not unique but merely strengthen the need for an ultrasound assessment as an essential obstetric service in LMICs and as per WHO recommendations [4]. Consistent with our findings, the use of ultrasound dating correctly predicted date of delivery within 14 days of actual delivery in 85% and 91% of the study cohort in two other studies respectively [11, 29]. In these studies, use of a paper pregnancy wheel to calculate gestational age and EDD could have also contributed to the weaker ability to correctly predict the EDD based on LMP dating [30, 31]. These studies have demonstrated inconsistencies in determining EDDs using paper pregnancy wheels of various types. Many of these pregnancy wheels deviated from the standard pregnancy duration of 280 days [30]. The ACOG smartphone app offers the option of using LMP dating alone in the absence of an ultrasound, or an ultrasound alone or a combination of both methods. Using smartphone technology that is widely available in most LMIC countries, and ultrasound dating when available would provide women and clinicians more accurate estimates of expected date of delivery and could reduce maternal and perinatal morbidity associated with non-facility based deliveries.

The implications of an inaccurate EDD are two-fold. As an intervention to minimize the number of non-facility based deliveries and associated adverse pregnancy outcomes, women in rural resource limited settings are advised to pre-arrange suitable transport to their nearest maternity hospital in advance of their due date for delivery. In a study of more than 4000 women in Zanzibar, 28% of EDDs were overestimated ie. beyond the ADD and as a result these women were less likely to deliver at a health facility [28]. Not delivering at a health facility or delay in presenting to the health facility when in labour has a major impact on perinatal and maternal morbidity and mortality. The other clinical implication of inaccurate EDDs derived from LMP lies in the misclassification of preterm and post-term births. In our study, using LMP in the absence of an EUS would have misclassified 10% of the term births as preterm (< 37 weeks) and 11% as post-term (> 41 weeks). Other studies have reported similar misclassifications [17, 25, 32]. More importantly, such misclassifications have also been reported in large scale surveillance reports. A prospective study carried out in the Western Cape, SA to elucidate reasons for inconsistent associations between antiretroviral use and preterm birth had similar findings to our study with there being a significantly greater number of pre- and post-term deliveries in women who were not dated by ultrasound and that ultrasound-based dating was more accurate in predicting spontaneous labour than LMP or SFH based dating, both individually or in combination [33]. Tunon et al. compared ultrasound to a reliable LMP in predicting the ADD in 15 000 women and showed that there was a significantly narrower distribution of births according to the ultrasound estimates and the proportion post-term births were significantly greater by LMP versus ultrasound dating methods [34]. A more recent study conducted in Johannesburg, SA, concluded that in the absence of ultrasound, LMP is a reliable alternative for GA dating during early pregnancy [11]. However, it is not sensitive in identifying late- and post-term pregnancies and should not be relied upon to make clinical decisions regarding elective cesarean section or induction of labor for supposed prolonged pregnancies.

Our study findings highlight a potential preventable factor in reducing perinatal morbidity and mortality. In the absence of dating by EUS, pregnancies may complicate with the potential to contribute to the burden of prematurity, unnecessary inductions of labour in already resource-constrained settings and undiagnosed post-term pregnancies with its attendant risks of perinatal morbidity and mortality. Additionally, the largest category of perinatal deaths in SA is unexplained stillbirth, of which up to one-quarter have intrauterine growth restriction [14], another risk that may be modified by improved pregnancy dating.

The strength of our study lies in the head-to-head comparison of LMP and EUS dating in a healthy pregnant population. This is the first study that evaluates a Smartphone app in a research setting. While we are aware that an US report may or may not be available some time after the 1st antenatal visit in resource limited settings, the Smartphone app should be further evaluated in the primary health care setting where there is an expected discrepancy in EDD between LMP dating at the 1st visit and an US report at later visits. For comparative purposes, our smaller sample size is limiting. Our other limitation is the absence of SFH measurements however the high proportion of obesity in our local population could likely not have been reliably measured in almost 30% of the population.

Conclusions

EUS alone and the Smartphone App method of pregnancy dating are the most accurate methods to estimate the EDD in a cohort of healthy South African pregnant women. The use of LMP-based dating method results in the misclassification of a significantly greater number of preterm and post-term deliveries compared to EUS and Smartphone App dating methods.

Availability of data and materials

The datasets used and/or analysed during the current study available from the corresponding author on reasonable request.

Abbreviations

GA:

Gestational Age

EDD:

Expected Date of Delivery

ADD:

Actual Date of Delivery

US:

Ultrasound

EUS:

Early Ultrasound

LMP:

Last Menstrual Period

LMIC:

Low and Middle Income Country

SFH:

Symphysis Fundal Height

BMI:

Body Mass Index

RCT:

Randomised Control Trial

TDF/FTC:

Tenofovir diphosphate fumarate/Emtricitabine

References

  1. Committee Opinion No 700: Methods for Estimating the Due Date. Obstet Gynecol. 2017;129(5):e150-e154. doi: https://0-doi-org.brum.beds.ac.uk/10.1097/AOG.0000000000002046. PMID: 28426621.

  2. Reis ZSN, Gaspar JS, Vitral GLN, et al. Quality of Pregnancy Dating and Obstetric Interventions During Labor: Retrospective Database Analysis. JMIR Pediatr Parent. 2020;3(1): e14109. https://0-doi-org.brum.beds.ac.uk/10.2196/14109 (PMID:32293572;PMCID:PMC7191349).

    Article  PubMed  PubMed Central  Google Scholar 

  3. Jones RM, Vesel L, Kimenju G, et al. Implementation of the INTERGROWTH-21st gestational dating and fetal and newborn growth standards in Nairobi, Kenya: women’s experiences with ultrasound and newborn assessment. Glob Health Action. 2020;13(1):1770967. https://0-doi-org.brum.beds.ac.uk/10.1080/16549716.2020.1770967 (PMID:32544027;PMCID:PMC7480435).

    Article  PubMed  PubMed Central  Google Scholar 

  4. World Health Organisation. WHO recommendations on antenatal care for a positive pregnancy experience. https://www.who.int/publications/i/item/9789241549912. Accessed 12Mar2021.

  5. McClure EM, Nathan RO, Saleem S, et al. First look: a cluster randomized trial of ultrasound to improve pregnancy outcomes in low income country settings. BMC Pregnancy Childbirth. 2014;14:73. https://0-doi-org.brum.beds.ac.uk/10.1186/1471-2393-14-73.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Swanson DL, Franklin HL, Swanson JO, et al. Including ultrasound scans in antenatal care in low-resource settings: Considering the complementarity of obstetric ultrasound screening and maternity waiting homes in strengthening referral systems in low-resource, rural settings. Semin Perinatol. 2019;43(5):273–281. doi: https://0-doi-org.brum.beds.ac.uk/10.1053/j.semperi.2019.03.017. Epub 2019 Mar 16. PMID: 30979599; PMCID: PMC6597951.

  7. Scott K, Gupta S, Williams E, Arthur M, Somayajulu UV, Noguchi L. “I can guess the month … but beyond that, I can’t tell” an exploratory qualitative study of health care provider perspectives on gestational age estimation in Rajasthan, India. BMC Pregnancy Childbirth. 2020;20(1):529. https://0-doi-org.brum.beds.ac.uk/10.1186/s12884-020-03201-6.PMID:32917163;PMCID:PMC7488485.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Puoane T, Steyn K, Bradshaw D, et al. Obesity in South Africa: The South African demographic and health survey. Obes Res. 2002;10(10):1038–48.

    Article  Google Scholar 

  9. Morin I, Morin L, Zhang X, et al. Determinants and consequences of discrepancies in menstrual and ultrasonographic gestational age estimates. BJOG. 2005;112:145–52.

    Article  Google Scholar 

  10. Olesen AW, Westergaard JG, Thomsen SG, Olsen J. Correlation between self-reported gestational age and ultrasound measurements. Acta Obstetricia et Gynecologica Scandinavica. 2004;83:1039–43.

    Article  Google Scholar 

  11. Geerts L, Theron G. A comparison of pregnancy dating methods commonly used in South Africa: A prospective study. S Afr Med J. 2013;103(8):552–6. https://0-doi-org.brum.beds.ac.uk/10.7196/SAMJ.6751.

    Article  PubMed  Google Scholar 

  12. Schulte J, Dominguez K, Sukalac T, Bohannon B, Fowler MG. Pediatric Spectrum of HIV Disease Consortium. Declines in low birth weight and preterm birth among infants who were born to HIV-infected women during an era of increased use of maternal antiretroviral drugs: Pediatric Spectrum of HIV Disease, 1989–2004. Pediatrics. 2007;119(4):e900–6. doi: https://0-doi-org.brum.beds.ac.uk/10.1542/peds.2006-1123. Epub 2007 Mar 12. PMID: 17353299.

  13. Mehta UC, van Schalkwyk C, Naidoo P, Ramkissoon A, Mhlongo O, Maharaj NR, Naidoo N, Fieggen K, Urban MF, Krog S, Welte A, Dheda M, Pillay Y, Moran NF. Birth outcomes following antiretroviral exposure during pregnancy: Initial results from a pregnancy exposure registry in South Africa. South Afr J HIV Med. 2019;20(1):971. https://0-doi-org.brum.beds.ac.uk/10.4102/sajhivmed.v20i1.971 (PMID:31616571;PMCID:PMC6779987).

    Article  PubMed  PubMed Central  Google Scholar 

  14. Lynch CD, Zhang J. The research implications of the selection of a gestational age estimation method. Paediatr Perinat Epidemiol. 2007;21(Suppl 2):86–96. https://0-doi-org.brum.beds.ac.uk/10.1111/j.1365-3016.2007.00865.x (PMID: 17803622).

    Article  PubMed  Google Scholar 

  15. Fowler MG, Qin M, Fiscus SA, Currier JS, Flynn PM, Chipato T, McIntyre J, Gnanashanmugam D, Siberry GK, Coletti AS, Taha TE, Klingman KL, Martinson FE, Owor M, Violari A, Moodley D, Theron GB, Bhosale R, Bobat R, Chi BH, Strehlau R, Mlay P, Loftis AJ, Browning R, Fenton T, Purdue L, Basar M, Shapiro DE, Mofenson LM; IMPAACT 1077BF/1077FF PROMISE Study Team. Benefits and Risks of Antiretroviral Therapy for Perinatal HIV Prevention. N Engl J Med. 2016 Nov 3;375(18):1726–1737. doi: https://0-doi-org.brum.beds.ac.uk/10.1056/NEJMoa1511691. PMID: 27806243; PMCID: PMC5214343.

  16. Kourtis AP, Fowler MG. Antiretroviral use during pregnancy and risk of preterm delivery: more questions than answers. J Infect Dis. 2011;204(4):493–4. https://0-doi-org.brum.beds.ac.uk/10.1093/infdis/jir318 (PMID: 21791648).

    Article  PubMed  Google Scholar 

  17. Venkatesh KK, Farhad M, Fenton T, Moodley D, Naik S, Nakabiito C, Fairlie L, Fowler MG, Stringer JSA, Chi BH. Association between HIV antiretroviral therapy and preterm birth based on antenatal ultrasound gestational age determination: a comparative analysis. AIDS. 2019;33(15):2403–13. https://0-doi-org.brum.beds.ac.uk/10.1097/QAD.0000000000002367 (PMID:31764105;PMCID:PMC7293898).

    Article  PubMed  Google Scholar 

  18. Hadlock FP, Deter RL, Harrist RB, Park SK. Estimating fetal age: Computer-assisted analysis of multiple fetal growth parameters. Radiology. 1984;152:497.

    Article  CAS  Google Scholar 

  19. Bland JM. Altman DG Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;327(8476):307–10.

    Article  Google Scholar 

  20. Geirsson RT. Ultrasound instead of last menstrual period as the basis of gestational age assignment. Ultrasound Obstet Gynecol 1991;1(3):212–219. http://0-dx-doi-org.brum.beds.ac.uk/10.1046/j.1469-0705.1991.01030212

  21. Gjessing HK, Skjaerven R, Wilcox AJ. Errors in gestational age: evidence of bleeding early in pregnancy. Am J Public Health. 1999;89:213–8.

    Article  CAS  Google Scholar 

  22. Kramer MS, McLean FH, Boyd ME, Usher RH. The validity of gestational age estimation by menstrual dating in term, preterm, and postterm gestations. JAMA. 1988;260:3306–8.

    Article  CAS  Google Scholar 

  23. Gardosi J, Geirsson RT. Routine ultrasound is the method of choice for dating pregnancy. Brit J Obstet Gynaecol. 1998;105:933–6.

    Article  CAS  Google Scholar 

  24. Savitz DA, Terry JW, Dole N, Thorp JM, Siega-Riz AM, Herring AH. Comparison of pregnancy dating by last menstrual period, ultrasound scanning, and their combination. Am J Obstet Gynecol. 2002;187:1660–6.

    Article  Google Scholar 

  25. Sharma LK, Bindal J, Shrivastava VA, Sharma M, Choorakuttil RM, Nirmalan PK. Discordant dating of pregnancy by LMP and ultrasound and its implications in perinatal statistics. Indian J Radiol Imaging. 2020;30(1):27–31. doi: https://0-doi-org.brum.beds.ac.uk/10.4103/ijri.IJRI_383_19. Epub 2020 Mar 30. PMID: 32476747; PMCID:

  26. Fraser IS. Vaginal bleeding patterns in women using once-a-month injectable contraceptives. Contraception. 1994;49(4):399–420. https://0-doi-org.brum.beds.ac.uk/10.1016/0010-7824(94)90035-3 (PMID: 8013222).

    Article  CAS  PubMed  Google Scholar 

  27. Waldenström U, Axelsson O, Nilsson S. Sonographic dating of pregnancies among women with menstrual irregularities. Acta Obstet Gynecol Scand. 1991;70(1):17–20. https://0-doi-org.brum.beds.ac.uk/10.3109/00016349109006171 (PMID: 1858490).

    Article  PubMed  Google Scholar 

  28. Fulcher I, Hedt K, Marealle S, Tibaijuka J, Abdalla O, Hofmann R, Layer E, Mitchell M, Hedt-Gauthier B. Errors in estimated gestational ages reduce the likelihood of health facility deliveries: results from an observational cohort study in Zanzibar. BMC Health Serv Res. 2020;20(1):50. https://0-doi-org.brum.beds.ac.uk/10.1186/s12913-020-4904-5 (PMID:31959165;PMCID:PMC6972023).

    Article  PubMed  PubMed Central  Google Scholar 

  29. Jehan I, Zaidi S, Rizvi S, Mobeen N, McClure EM, Munoz B, Pasha O, Wright LL, Goldenberg RL. Dating gestational age by last menstrual period, symphysis-fundal height, and ultrasound in urban Pakistan. Int J Gynaecol Obstet. 2010;110(3):231–4. https://0-doi-org.brum.beds.ac.uk/10.1016/j.ijgo.2010.03.030 (PMID:20537328;PMCID:PMC2914118).

    Article  PubMed  PubMed Central  Google Scholar 

  30. Chambliss LR, Clark SL. Paper gestational age wheels are generally inaccurate. Am J Obstet Gynecol. 2014;210(2):145.e1-4. https://0-doi-org.brum.beds.ac.uk/10.1016/j.ajog.2013.09.013 (Epub 2013 Sep 11 PMID: 24036402).

    Article  Google Scholar 

  31. Ross MG. Circle of time: errors in the use of the pregnancy wheel. J Maternal-Fetal Neonatal Med. 2003;14(6):370–2. https://0-doi-org.brum.beds.ac.uk/10.1080/14767050412331312200.

    Article  CAS  Google Scholar 

  32. Price JT, Winston J, Vwalika B, Cole SR, Stoner MCD, Lubeya MK, Kumwenda A, Stringer JSA. Quantifying bias between reported last menstrual period and ultrasonography estimates of gestational age in Lusaka, Zambia. Int J Gynaecol Obstet. 2019;144(1):9–15. doi: https://0-doi-org.brum.beds.ac.uk/10.1002/ijgo.12686. Epub 2018 Oct 19. PMID: 30267538; PMCID: PMC6283668.

  33. Malaba TR, Newell ML, Madlala H, Perez A, Gray C, Myer L. Methods of gestational age assessment influence the observed association between antiretroviral therapy exposure, preterm delivery, and small-for-gestational age infants: a prospective study in Cape Town. South Africa Ann Epidemiol. 2018;28(12):893–900.

    Article  Google Scholar 

  34. Tunón K, Eik-Nes SH, Grøttum P. A comparison between ultrasound and a reliable last menstrual period as predictors of the day of delivery in 15,000 examinations. Ultrasound Obstet Gynecol. 1996;8(3):178–85. https://0-doi-org.brum.beds.ac.uk/10.1046/j.1469-0705.1996.08030178.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank the Data Management and Nursing Teams at the Umlazi Clinical Research Site that assisted with data collection and preparation of the data set.

Funding

This substudy did not receive funding however the parent study was supported by funding received from Gilead Sciences Inc and South African Medical Research Council.

Author information

Authors and Affiliations

Authors

Contributions

LM, SB and DM conceptualized the study. VG, MN and ZG collected the data. CL analysed the data and provided statistical guidance to interpreting and presenting the findings. LM, SB and DM wrote the first draft and all authors contributed to the final version of the manuscript. The author(s) read and approved the final manuscript. 

Corresponding author

Correspondence to Dhayendre Moodley.

Ethics declarations

Ethics approval and consent to participate

The Institutional Review Board of University of KwaZulu-Natal approved the parent study (BFC 243/16) for which participants provided a written informed consent. The substudy (Ref BE 00,000,817/201) which was a retrospective analysis of de-identified data was also approved by the Institutional Review Board of University of KwaZulu-Natal (UKZN IRB) and did not require participant consent. We can confirm that the study was conducted in accordance with the South African GCP Guidelines, Department of Health guidelines and under the watch of the UKZN IRB.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Majola, L., Budhram, S., Govender, V. et al. Reliability of last menstrual period recall, an early ultrasound and a Smartphone App in predicting date of delivery and classification of preterm and post-term births. BMC Pregnancy Childbirth 21, 493 (2021). https://0-doi-org.brum.beds.ac.uk/10.1186/s12884-021-03980-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12884-021-03980-6

Keywords