Skip to main content

Measurement of area difference ratio of Photoplethysmographic pulse wave in patients with pre-eclampsia

Abstract

Background

Preeclampsia (PE) is associated with an increase in maternal arterial stiffness, which may be reflected by photoplethysmography (PPG) of the pulse wave. The aim of this study was to investigate area difference ratio (ADR), a novel parameter derived from PPG, in women with and without preeclampsia.

Methods

Patients with and without preeclampsia in the third trimester were enrolled. All patients had photoplethysmography of the pulse wave assessed. ADR was compared between the two groups.

Results

Seventy-two patients in the third trimester of gestation, of which 36 had preeclampsia and 36 did not, were enrolled. The ADR was lower in the preeclampsia group vs. the non-preeclampsia group (0.725 [IQR 0.681ā€“0.779] vs. 0.752 [IQR 0.717ā€“0.910], Pā€‰<ā€‰0.01).

Conclusions

Measuring the ADR through analyzing PPG of the pulse wave may be a useful diagnostic tool in patients with preeclampsia.

Peer Review reports

Background

Preeclampsia remains one of the leading causes of maternal and fetal morbidity and mortality worldwide, affecting 2ā€“3% of all pregnancies in the USA and 7.5% globally [1, 2]. The disease is characterized by hypertension, proteinuria and vascular dysfunction [3,4,5], and the pathophysiology of preeclampsia may involve an increase in arterial wall rigidity as a result of maternal endothelial dysfunction [6, 7]. Arterial stiffness can be assessed by measuring various parameters, including pulse wave velocity (PWV) and augmentation index (AIx) [6, 8,9,10,11,12]. As arterial stiffness is associated with an increased risk of having a cardiovascular event in healthy non-pregnant subjects [13], PWV and Aix may be helpful in predicting morbidity and mortality in preeclampsia. Similarly, PWV and Aix may also be used to provide information on arterial compliance in preeclampsia [8, 11, 14, 15].

Photoplethysmography (PPG) is a non-invasive and readily available optical technique that uses infrared light to illuminate the fingertip tissue and measures variations in light intensity that correspond to blood vessel volume [16, 17]. Previous studies have demonstrated that the contour of the PPG contains similar information to that of the peripheral pressure wave and may be used to evaluate arterial stiffness [18,19,20].

The diastolic decay constant (a function of vessel resistance and compliance) [21, 22] is associated with physiological changes of the cardiovascular system and is useful in vascular assessment [20, 22,23,24,25]. However, it is difficult to extract from the finger PPG pulse waveform. As such, the area difference ratio (ADR) was developed using a novel, non-iterative, shape method from the PPG waveform to serve as a parameter that is more readily established than the diastolic decay constant.

The aim of this study was to better understand the pathophysiology of preeclampsia by measuring the ADR in patients with or without preeclampsia at the time of disease. Our hypothesis was that the ADR would be lower in patients with preeclampsia.

Methods

Study population

The study protocol was approved by the Research Ethics Committee of the Womenā€™s Hospital, School of Medicine, Zhejiang University, and written informed consent was obtained from all patients who participated in the study. Patients with singleton pregnancies of at least 28Ā weeks gestational age were enrolled during a routine prenatal screening at the obstetrics clinic into one of two groups: the preeclampsia group (PE) or the non-preeclampsia group (Non-PE). Patients were enrolled in the PE group if they had a systolic blood pressure (SBP) ā‰„140Ā mmHg or diastolic blood pressure (DBP) ā‰„90Ā mmHg measured on two separate occasions at least 6Ā h apart, and proteinuria of ā‰„0.3Ā g/L in a 24Ā h urine collection that started after 20Ā weeks of pregnancy [26]. Pregnant women were excluded if they had gestational diabetes, essential hypertension, renal disease, history of tobacco use, and alcohol or illicit drug abuse.

Pulse wave analysis

Women who consented to the study were instructed to fast for at least 12Ā h prior to the study. Baseline demographic data were gathered upon the start of the study. All participants were instructed to sit comfortably with her arm supported on a table in a room whose temperature was maintained at 24Ā Ā°C. After at least 10Ā min of rest, the SBP and DBP were measured twice and the mean calculated. An adult oxygen sensor (DS-100A Durasensor, OxiMax, Nellcor Puritan Bennett, Inc.) was placed on the index finger of the non-dominant arm of pregnant woman to detect and collect PPG signal at a rate of 250Ā Hz. PPG measurements were performed 3 times over 5Ā min intervals and the mean calculated. Data was stored on a computer with specialized software we developed to calculate ADR, PPG amplitude (PPGA) and pulse beat interval (PBI). ADR was calculated as the difference between the area of the triangle (St) formed by points B, P, and O, and the area under the curve of the pulse (Sp) but above the horizontal line formed by points B and O, divided by St, as follows (see Fig.Ā 1 for points referenced) [21]: ADRā€‰=ā€‰(St ā€“ Sp) / St. PPGA was calculated as the difference of magnitude between point P and baseline. PBI was calculated as the time difference between point A and point B.

Fig. 1
figure 1

A representive beat of pulse photoplethysmographic waveform. Baseline is corrected to 0. Point A, P and B are the onset, peak and end position of pulse, respectively. Point O is the vertical projection of point P on the baseline. PPG signal (āˆ’) is shown with PPG magnitude in arbitrary units (au)

Statistical analysis

All statistical analyses were performed using Graphpad Prism 4 (Graphpad software Inc., San Diego, CA, USA). A P-value of <ā€‰0.05 was considered statistically significant. The Kolmogorov-Smirnov test was used to assess for Gaussian distribution. Data were expressed as meanā€‰Ā±ā€‰standard deviation (S.D.) or as median and interquartile range (IQR) for normally and non-normally distributed data, respectively. Comparisons between groups were performed using Studentā€™s t-test and the Chi-squared test were used for parametrically distributed continuous and categorical variables, respectively, and the Mann-Whitney U test was used for non-parametrically distributed continuous variables. A multivariate regression model was used to analyze the association of ADR with maternal demographic and hemodynamic data.

Results

A total of 72 pregnant women, 36 in the PE group and 36 in the Non-PE group, enrolled in the study between June 1 and December 31, 2016. The PE group consisted of 30 patients with mild and 6 patients with severe preeclampsia. Twenty-three patients in the PE group were taking antihypertensive medications, including Ī²-blockers (14 patients), Ī²-blockers and Calcium channel blockers (9 patients), or Calcium channel blockers (3 patients). A total of 26 patients had early onset (<ā€‰34Ā weeks) preeclampsia and 10 had late onset (>ā€‰34Ā weeks) preeclampsia.

Baseline demographic data of study participants are presented in TableĀ 1. There were no statistically significant differences between the groups in maternal age, gestational age at enrollment, or fetal sex. The PE group exhibited higher weight, higher body mass index, shorter height, and lower birth weight. Gestational age at delivery was significantly earlier in the PE group than in normal pregnant women.

Table 1 Demographic data for pregnant women: normal and preeclampsia

Multivariate regression analysis found no significant associations between ADR and height (Pā€‰=ā€‰0.94), weight (Pā€‰=Ā 0.83), SBP (Pā€‰=Ā 0.85), and DBP,(Pā€‰=Ā 0.83).

SBP, DBP, mean arterial pressure, PPGA, PBI, and ADR are presented in TableĀ 2. The PPGA and PBI were not significantly different between the groups. Conversely, patients in the PE group had a lower ADR decreased and higher SBP, DBP, and MAP. The ADR returned to baseline 42Ā days postpartum in the PE group (see Fig.Ā 2).

Table 2 Vascular characteristics of the study populations
Fig. 2
figure 2

Box and whisker plots comparing the ADR in the PE group during pregnancy (left), and postpartum (right). Boxes represent IQR, where the line represents the median. Whiskers at top and bottom of the box represent the highest and lowest values

Discussion

In this study, we observed that patients with preeclampsia have a lower ADR compared to those without preeclampsia during the early third trimester. No differences were observed in PPGA and PBI between the two groups.

Our primary finding that preeclampsia was associated with a lower ADR is consistent with our initial hypothesis. The ADR is closely correlated to the diastolic decay constant, a parameter that describes the exponential rate at which arterial pressure decreases during diastole [21, 22]. An accelerated diastolic decay constant is associated with greater arterial stiffness and therefore hypertension. By measuring the diastolic decay constant with invasive arterial blood pressuring monitoring we can further characterize resistance and total arterial compliance [27]. In addition, one of the major advantages of the diastolic decay constant is that local factors, including perfusion, do not significantly alter its value [28,29,30]. However, the invasive nature of this test limits its clinical utility on the labor and delivery unit.

The major advantage of PPG is that it is a non-invasive technique that can measure various parameters associated with the pulse wave. While several parameters from the PPG pulse wave have been measured, including the PPG amplitude and the PPG notch position and notch relative amplitude, none have demonstrated clinical utility [31,32,33,34]. Furthermore, environmental factors, metabolic state, motion artifact and psychological wellbeing all influence these parameters and make interpretation of those parameters unreliable [35, 36]. On the other hand, the major advantage of the ADR is that the effect of PPG magnitude is eliminated in its calculation and therefore makes it more reliable [21]. The only limitation of the ADR is that pre-calibration is essential for a reliable measurement.

Preeclampsia is characterized by a marked increase in peripheral vascular resistance and vasoconstriction [3,4,5], and increased sympathetic vasoconstrictor activity has been demonstrated with measurements of muscle sympathetic nerve activity [3, 37]. The etiology of the increased sympathetic tone is likely endothelial dysfunction [38,39,40,41]. It is important to note that endothelial dysfunction may be present in preeclampsia as this is an important step in the development of atherosclerosis in patients with chronic hypertension [42]. In non-pregnant patients with chronic hypertension, vascular disease or diabetes, vascular stiffness may be due to the decline of vascular compliance [43,44,45,46].

It is important to note that our study has several limitations. First, given the study design (cross-sectional study of women with preeclampsia at 30Ā weeks gestational age), our results describe pathophysiological changes of preeclampsia but do not necessarily indicate that the ADR is a useful tool in the prediction of preeclampsia. Second, while we believe that ADR may be a useful measure of arterial stiffness, we did not correlate the ADR to other established measures of arterial stiffness (e.g. PWV, Aix). Future studies should attempt to make that correlation. Third, given that increased sympathetic activity may be characteristic of pregnancy in the absence of neurological disease, digital blood flow and thus the waveform may have been affected by peripheral vasoconstriction. Nevertheless, the diastolic decay constant is a value derived from the waveform and might not be as significantly influenced by local perfusion.

Conclusions

Our study offer a new insight into the pathophysiologic features in preeclampsia. The results suggest that the ADR may be decreased in patients with preeclampsia, but our study does not tell us about the ability of the ADR to predict preeclampsia. Future studies should examine how ADR may be used to predict preeclampsia throughout pregnancy, whether predicting it early or later gestation.

Abbreviations

ADR:

area difference ratio

Aix:

augmentation index

AS:

arterial stiffness

DBP:

distolic blood pressure

MBP:

mean blood pressure

PBI:

pulse beat interval

PE:

preeclampsia

PPG:

photoplethysmography

PPGA:

photoplethysmography amplitude

PWV:

pulse wave velocity

SBP:

systolic blood pressure

References

  1. Abalos E, Cuesta C, Carroli G, Qureshi Z, Widmer M, Vogel JP, Souza JP. Maternal WHOMSo, newborn Health Research N: pre-eclampsia, eclampsia and adverse maternal and perinatal outcomes: a secondary analysis of the World Health Organization multicountry survey on maternal and newborn health. BJOG. 2014;121(Suppl 1):14ā€“24.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  2. Ananth CV, Keyes KM, Wapner RJ. Pre-eclampsia rates in the United States, 1980-2010: age-period-cohort analysis. BMJ. 2013;347:f6564.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  3. Schobel HP, Fischer T, Heuszer K, Geiger H, Schmieder RE. Preeclampsia -- a state of sympathetic overactivity. N Engl J Med. 1996;335:1480ā€“5.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  4. Roberts JM, Redman CW. Pre-eclampsia: more than pregnancy-induced hypertension. Lancet. 1993;341:1447ā€“51.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  5. Roberts JM, Taylor RN, Goldfien A. Clinical and biochemical evidence of endothelial cell dysfunction in the pregnancy syndrome preeclampsia. Am J Hypertens. 1991;4:700ā€“8.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  6. Kaihura C, Savvidou MD, Anderson JM, McEniery CM, Nicolaides KH. Maternal arterial stiffness in pregnancies affected by preeclampsia. Am J Physiol Heart Circ Physiol. 2009;297:H759ā€“64.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  7. Avni B, Frenkel G, Shahar L, Golik A, Sherman D, Dishy V. Aortic stiffness in normal and hypertensive pregnancy. Blood Press. 2010;19:11ā€“5.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  8. Spasojevic M, Smith SA, Morris JM, Gallery ED. Peripheral arterial pulse wave analysis in women with pre-eclampsia and gestational hypertension. Bjog. 2005;112:1475ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  9. Ronnback M, Lampinen K, Groop PH, Kaaja R. Pulse wave reflection in currently and previously preeclamptic women. Hypertens Pregnancy. 2005;24:171ā€“80.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  10. Robb AO, Mills NL, Din JN, Smith IB, Paterson F, Newby DE, Denison FC. Influence of the menstrual cycle, pregnancy, and preeclampsia on arterial stiffness. Hypertension. 2009;53:952ā€“8.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  11. Khalil A, Jauniaux E, Harrington K. Antihypertensive therapy and central hemodynamics in women with hypertensive disorders in pregnancy. Obstet Gynecol. 2009;113:646ā€“54.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  12. Elvan-Taspinar A, Franx A, Bots ML, Bruinse HW, Koomans HA. Central hemodynamics of hypertensive disorders in pregnancy. Am J Hypertens. 2004;17:941ā€“6.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  13. Mitchell GF, Hwang SJ, Vasan RS, Larson MG, Pencina MJ, Hamburg NM, Vita JA, Levy D, Benjamin EJ. Arterial stiffness and cardiovascular events: the Framingham heart study. Circulation. 2010;121:505ā€“11.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  14. Tomimatsu T, Fujime M, Kanayama T, Mimura K, Koyama S, Kanagawa T, Endo M, Shimoya K, Kimura T. Abnormal pressure-wave reflection in pregnant women with chronic hypertension: association with maternal and fetal outcomes. Hypertens Res. 2014;37:989ā€“92.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  15. Oylumlu MOM, Yuksel M, Yildiz A, Bilik MZ, Akil MA, Ozler A, Acet H, Ertas F, Alan S. A simple method for the assessment of arterial stiffness in pre-eclamptic patients. Clin Exp Hypertens. 2014;36:7.

    Google ScholarĀ 

  16. Morikawa Y. Characteristic pulse wave caused by organic nitrates. Nature. 1967;213:841ā€“2.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  17. Lund F. Digital pulse plethysmography (DPG) in studies of the hemodynamic response to nitrates--a survey of recording methods and principles of analysis. Acta Pharmacol Toxicol. 1986;59:18.

    Google ScholarĀ 

  18. Millasseau SC, Guigui FG, Kelly RP, Prasad K, Cockcroft JR, Ritter JM, Chowienczyk PJ. Noninvasive assessment of the digital volume pulse. Comparison with the peripheral pressure pulse. Hypertension. 2000;36:952ā€“6.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  19. Millasseau SC, Kelly RP, Ritter JM, Chowienczyk PJ. Determination of age-related increases in large artery stiffness by digital pulse contour analysis. Clin Sci (Lond). 2002;103:371ā€“7.

    ArticleĀ  CASĀ  Google ScholarĀ 

  20. Takazawa K, Tanaka N, Fujita M, Matsuoka O, Saiki T, Aikawa M, Tamura S, Ibukiyama C. Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension. 1998;32:365ā€“70.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  21. HOU LX W, Wang X, Chen XZ, Feng Y, Jiang K. A novel noniterative shape method for estimating the decay time constant of the finger photoplethysmographic pulse. J Zhejiang Univ-SCI Appl Physics Engineering. 2011;12:8.

    Google ScholarĀ 

  22. Lu S, Zhao H, Ju K, Shin K, Lee M, Shelley K, Chon KH. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? J Clin Monit Comput. 2008;22:23ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  23. Segers P, Verdonck P, Deryck Y, Brimioulle S, Naeije R, Carlier S, Stergiopulos N. Pulse pressure method and the area method for the estimation of total arterial compliance in dogs: sensitivity to wave reflection intensity. Ann Biomed Eng. 1999;27:480ā€“5.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  24. Bhattacharya J, Kanjilal PP, Muralidhar V. Analysis and characterization of photo-plethysmographic signal. IEEE Trans Biomed Eng. 2001;48:5ā€“11.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  25. Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28:R1ā€“39.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  26. ACOG practice bulletin. Diagnosis and management of preeclampsia and eclampsia. Number 33, January 2002. Obstet Gynecol. 2002;99:159ā€“67.

    Google ScholarĀ 

  27. Milnor WR. Cardiovascular physiology, Oxford university press, New York. New York: Oxford University Press; 1990.

    Google ScholarĀ 

  28. Millasseau SC, Ritter JM, Takazawa K, Chowienczyk PJ. Contour analysis of the photoplethysmographic pulse measured at the finger. J Hypertens. 2006;24:1449ā€“56.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  29. Chowienczyk PJ, Kelly RP, MacCallum H, Millasseau SC, Andersson TL, Gosling RG, Ritter JM, Anggard EE. Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus. J Am Coll Cardiol. 1999;34:2007ā€“14.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  30. Lax H, Feinberg AW, Cohen BM. Studies of the arterial pulse wave. J Chronic Dis. 1956;3:618ā€“31.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  31. Chen X, Thee C, Gruenewald M, Wnent J, Illies C, Hoecker J, Hanss R, Steinfath M, Bein B. Comparison of surgical stress index-guided analgesia with standard clinical practice during routine general anesthesia: a pilot study. Anesthesiology. 2010;112:1175ā€“83.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  32. Huiku M, Uutela K, van Gils M, Korhonen I, Kymalainen M, Merilainen P, Paloheimo M, Rantanen M, Takala P, Viertio-Oja H, Yli-Hankala A. Assessment of surgical stress during general anaesthesia. Br J Anaesth. 2007;98:447ā€“55.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  33. Ahonen J, Jokela R, Uutela K, Huiku M. Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery. Br J Anaesth. 2007;98:456ā€“61.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  34. Seitsonen ER, Korhonen IK, van Gils MJ, Huiku M, Lotjonen JM, Korttila KT, Yli-Hankala AM. EEG spectral entropy, heart rate, photoplethysmography and motor responses to skin incision during sevoflurane anaesthesia. Acta Anaesthesiol Scand. 2005;49:284ā€“92.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  35. Zahedi E, Chellappan K, Ali MA, Singh H. Analysis of the effect of ageing on rising edge characteristics of the photoplethysmogram using a modified Windkessel model. Cardiovasc Eng. 2007;7:172ā€“81.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  36. Reisner A, Shaltis PA, McCombie D, Asada HH. Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology. 2008;108:950ā€“8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  37. Greenwood JP, Scott EM, Walker JJ, Stoker JB, Mary DA. The magnitude of sympathetic hyperactivity in pregnancy-induced hypertension and preeclampsia. Am J Hypertens. 2003;16:194ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  38. VanWijk MJ, Kublickiene K, Boer K, VanBavel E. Vascular function in preeclampsia. Cardiovasc Res. 2000;47:38ā€“48.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  39. Powe CE, Levine RJ, Karumanchi SA. Preeclampsia, a disease of the maternal endothelium: the role of antiangiogenic factors and implications for later cardiovascular disease. Circulation. 2011;123:2856ā€“69.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  40. Steegers EA, von Dadelszen P, Duvekot JJ, Pijnenborg R. Pre-eclampsia. Lancet. 2010;376:631ā€“44.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  41. Savvidou MD, Hingorani AD, Tsikas D, Frolich JC, Vallance P, Nicolaides KH. Endothelial dysfunction and raised plasma concentrations of asymmetric dimethylarginine in pregnant women who subsequently develop pre-eclampsia. Lancet. 2003;361:1511ā€“7.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  42. Davignon J, Ganz P. Role of endothelial dysfunction in atherosclerosis. Circulation. 2004;109:III27ā€“32.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  43. Liao D, Arnett DK, Tyroler HA, Riley WA, Chambless LE, Szklo M, Heiss G. Arterial stiffness and the development of hypertension. The ARIC study. Hypertension. 1999;34:201ā€“6.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  44. McVeigh GE, Bratteli CW, Morgan DJ, Alinder CM, Glasser SP, Finkelstein SM, Cohn JN. Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance. Hypertension. 1999;33:1392ā€“8.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  45. Cohn JN, Finkelstein S, McVeigh G, Morgan D, LeMay L, Robinson J, Mock J. Noninvasive pulse wave analysis for the early detection of vascular disease. Hypertension. 1995;26:503ā€“8.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

  46. McVeigh GE, Morgan DR, Allen P, Trimble M, Hamilton P, Dixon LJ, Silke B, Hayes JR. Early vascular abnormalities and de novo nitrate tolerance in diabetes mellitus. Diabetes Obes Metab. 2002;4:336ā€“41.

    ArticleĀ  PubMedĀ  CASĀ  Google ScholarĀ 

Download references

Funding

The present study was supported by the funding from National Natural Science Foundation of China (NSFC, No 81271237 and No 81471126) and the fund from Science Technology Department of Zhejiang Province (No 2014C33171N).

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

FY helped in designing and conducting the study, collecting the data and writing the manuscript. DD helped in analyzing and interpreting the data and revising the manuscript critically. ZB helped in conducting the study and collecting the data. WX helped in designing the study and analyzing the data. CX helped in designing the study, analyzing the data and writing the manuscript. All authors have read and approved the manuscript.

Corresponding author

Correspondence to Xinzhong Chen.

Ethics declarations

Ethics approval and consent to participate

The study protocol was approved by the local Research Ethics Committee of the Womenā€™s Hospital, School of Medicine, Zhejiang University and written informed consent was obtained from all patients who participated in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisherā€™s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Feng, Y., Drzymalski, D., Zhao, B. et al. Measurement of area difference ratio of Photoplethysmographic pulse wave in patients with pre-eclampsia. BMC Pregnancy Childbirth 18, 280 (2018). https://0-doi-org.brum.beds.ac.uk/10.1186/s12884-018-1914-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s12884-018-1914-y

Keywords